Industrial Construction Services, Inc.

Cement Core Specifications

Contact ICS for more information on core and core combination specifications.  

Core Thickness

Overall Panel Thickness

Weight per sq. ft.

3.2 mm 5.7 mm 2.16 lbs
4.0 mm 6.5 mm 2.45 lbs
6.0 mm 8.5 mm 3.30 lbs
8.0 mm 10.5 mm 3.92 lbs

Physical Properties

Data Summary for Arcoplast antimicrobial cement core panel 6 mm

 

 

 

 

ASTM D 638 Tensile Strength 5732 psi
ASTM D 638 Tensile Modulus 0.3119 Mpsi
ASTM D 790 Flexural Strength 11.4107 psi
ASTM D 790 Flexural Modulus 0.8179 Mpsi
ASTM D 695 Compressive Strength 7.431 psi
ASTM D 695 compressie Modulus 1.973 Mpso
ASTM D 2538 Barcol Hardness 35.8
ASTM D 523 Gloss Property 97.3 from light source
@ 85 degrees
ASTM D 696 Coefficent of linear
thermal expansion
31.4
10-6in/in/oF
ASTM E 96 Water Vapor
Transmission less that .01 perms
Mils 1073.2 Impact Resistance A 2 lb. steel ball dropped from 11'0" cause no damage on impact.

Surface Burning Characteristics of Materials

New York City Approval
#MEA 414-04-M

 

 

 

 

ASTM E 84 Flame Spread 19
ASTM E 84 Smoke Development 278

Composite Panels for Specific Design and Performance Requirements

Closed-Edge Insulated Cement Core Lay-In Modular Liners Wall and Ceiling Liners Wall and Partition Heavy Duty Walk-On

Toxicity
When tested in with the combustion toxicity protocol developed at the University of Pittsburgh, the Arcoplat cement core sandwhich panel meets the requirement for interior finish material as defined by Title 27, Chapter 1, Subchapter 5, Article 5, of the Building Code of the City of New York.